High Resolution Automatic Circle Polarimeters 0.001 degree

Features of Polartronic high resolution polarimeters

  • Highly accurate because of the direct linking of the optical analyzer and angle encoder
  • Short measuring time no need to return to zero position for new measurements
  • Automatic temperature compensation with temperature sensing tubes
  • 8 line LCD display panel is user configurable
  • Displays levorotory samples and the optical density up to 99.9%
  • Suitable for dynamic processes such as kinetic reactions
  • Built in RS232 interface
  • Works with Schmidt+Haensch refractometer (DUR-SW)) for simultaneous Pol and Brix.
  • Conforms to international standards ICUMSA, O.I.M.L., K157 US and other Pharmacopoeia methods
Polartronic series Automatic Digital Circle Polarimeters
 Polartronic polarimeters determine the optical activity of a solution by means of a rotating analyzer linked to an optical encoder. A special feature of the Schmidt & Haensch design is their high speed and accuracy. This is because of the direct linking of the polarizing analyzer to an optical position encoder, a technique originally patented by Schmidt+Haensch. This technique completely eliminates the linearity errors associated with other types of mechanical linkage and ensures that the accuracy is constant across the full range of the instrument. The Polartronics are designed for continuous measurement operation so that it is never necessary to return to a start or zero position in order to initiate a new measurement.
Comprehensive user interface
The control panel of the unit includes a numeric keyboard, function buttons and an 8 line LCD display. In the main display you see immediately, the sample ID, the measured rotation, time, date, temperature, wavelength and tube size. You can change parameters from this control panel - for example change scale, change wavelength, enter a sample ID, print the results. You can also format the printout and the display itself.
Range of polarimeter tubes
Polartronics work with all standard Polarimeters tubes as well as continuous flow tubes, micro tubes and temperature controlled tubes. There is a connection at the back of the sample compartment where the temperature sensors are plugged into the instruments electronics. Using this feature the polarimeter can make automatic temperature compensation. We have special tubes for temperature measurement and small tubes for precious samples. See more of our large range of Polarimeter tubes here.)
 
Flow through Polarimeters tube with temperature sensor 
Temperature sensor
Jacketed Polarimeter tube with flow connector
 
Multi Wavelength Polarimeters
The model HHW5 and HNQW5 include 5 different measurement wavelengths. The wavelengths are produced by a Halogen lamp and filters in the HHW5 and by Sodium and Mercury emission lamps and filters in the HNQW5. Wavelength is selected from the control panel and the correct lamp and filter are automatically activated by the electronics.
In addition the MH8 is available with two wavelengths (change manually) - MHW2.
Also HH8 and MH8 single wavelength Polarimeters are available with a different
interference filter for any wavelength in the range 350 - 900 nm instead of the standard 589 nm.
 

Specifications High Resolution (0.001 degree) Polarimeters

Model MH8 MW2 MHX HH8 HHX HHW5  HNQW5
Measuring Range +/- 85 degrees
Accuracy
(angular degrees)
+/- 0.002 +/- 0.002 +/- 0.002 +/-0.001  +/-0.001  +/-0.001 +/- 0.001
Balancing Time < 5 seconds-
Light source Halogen
lamp
Halogen
lamp
Halogen
lamp
Halogen
Lamp
Halogen
Lamp
Halogen
 Lamp
Sodium+
Mercury
Wavelengths /filters 589 nm 589 nm
+ 1 other
from
350-900
nm
any
single
from
350-900
nm
589 nm any
single
from
350-900
nm
589 nm
+ 4 
others
350-900
 nm
589 nm
546 nm
365 nm
436 nm
579 nm
Sensitivity up to 99.9% absorption
Measuring tubes up to 200 mm, all types, including temperature stable, micro and flow through
Temp comp. Automatic
Display 8 line LCD
Temperature Display Yes
Sample ID Yes
Communications RS232
Dimensions 733x425x195 mm-
Weight ~25 Kg-
Power Universal 110 / 230 Volts 100 VA
 
Applications
The Polartronic series circle polarimeters are suitable for concentration and purity analysis in many industrial and scientific applications including:
Food Industry
  • Transformation of glucose in fructose
  • Optical activity of carbohydrates and essential oils
  • Determination of the invert of sugar, lactose and starch
Pharmaceutical Industry
  • Control of DAB listed substances such as quinine-sulphate, ephedrine, benzil peniciline
  • Control of raw materials
  • Determination of sugar in urine
Cosmetics
  • Purity of essential oils and odiferous agents
Chemical Industry
  • Control of optically active chemicals

Ordering Information

Model Part Number
Polartronic MH8 single wavelength 589 nm TID 06010
Polartronic MHX any single wavelength in the range 350 - 900 nm TID 06910
Polartronic MW2 - MH8 with additional filter - in the range 350 - 900 nm TID 06900
Polartronic HH8 single wavelength 589 nm TID 06040
Polartronic HHX any single wavelength in the range 350 - 900 nm TID 06930
Polartronic HHW5 - with filter wheel for 5 filters 350 - 900 nm TID 06060
Polartronic HNQW5 sodium and mercury lamps 5 wavelengths TID 06050