"IAQ Point 2"
Touchscreen Indoor Air Quality Monitor



 

Why monitor Carbon Dioxide? High levels of CO2 can cause drowsiness and create an inefficient work environment for building occupants. To combat this problem, building managers may choose to run the ventilation system continuously, but this is an inefficient, costly practice. With IAQPoint2 in place, the ventilation system can do its job appropriately and efficiently, to the benefit of your bottom line.

Why monitor Volatile Organic Compounds? Increasingly, studies show a connection between the presence of VOCs (volatile organic compounds) and adverse health effects. Commercial, educational and government buildings contain VOCs by the thousands, such as:

• Organic odors, aerosols, disinfectants, cleansers (washrooms, kitchens)
• Paints, waxes, cleaning supplies, pesticides (janitorial closets)
• Copiers, printers, correction fluids, adhesives, permanent markers, photographic solutions (copier/printing rooms)
• Fuel cans, solvents, preservatives, automotive and vehicle products (warehouses, shipping areas)
• Formaldehyde carpets (offices and office areas)

IAQPoint2 detects these VOCs as well as many gases common to building areas including methane, carbon monoxide and nitrogen dioxide.


MAIN FEATURES:

 

User-Friendly Touchscreen Operation
• Menu driven, customizable, easy-to-navigate display
• Large 1.9 x 2.6 in (4.9 x 6.5 cm) VGA screen with
easy-to-read LCD digits and graphical display
Flexible, Money-Saving Design
• Simple wall- or duct-mount
• Multi-analog or digital (BACnet, Modbus) options
• DC and AC power; fits standard junction box
• 15 year sensor life with automatic self-calibration
• Adjustable set-points and optional relay for local
fan activation
3-in-1 Monitoring
• Choose reliable CO2 or VOC sensing technologies
• Optimize room comfort through temperature control
"Green" Attributes
• Obtain LEED credits
• Meet ASHRAE 62.1 standard
• Low power consumption and ‘sleep mode’ feature
• Optimize HVAC use and extend life of components


OTHER FEATURES:
Override feature – Reset demand control ventilation settings based on room occupancy (e.g. during off-peak hours)

Temp/rH sensor – Adjust room temperature at the touch of a button; eliminate extra IAQ devices

Calibration Port – Connect calibration tube for fast, accurate bump test; calibrate IAQPoint2 without opening the casing

CO2 or VOC sensor – Monitor gas concentration readings to drive demand-controlled ventilation; achieve savings and comfort by avoiding over or under-ventilation

USB Port – Update display graphics with logo and contact information; allow future uploads of product enhancements

Specifications

Model IAQPoint2 with CO2 Sensor IAQPoint2 with VOC Sensor
Gasses CO2 Volatile Organic Compounds (VOC)
Detection Method Non-dispersive infrared (NDIR) with ABC automatic background
calibration algorithm
Metal oxide semiconductor (MOS)
Range 0-2,000 ppm
0-5,000 ppm
0-100%
(400-2,000 ppm CO2 Equivalent)
Accuracy
± 30 ppm ± 5 % of reading
Response Time
T90 < 60 seconds
Calibration
No Calibration Required
Temperature Sensor
Detection Method Band Gap
Range --40° to 257°F (40° to 125°C)
Accuracy ±1°C at 25°C and 50% rH
Humidity Sensor
Detection Method Capacitive Type
Range 0-100% rH
Accuracy ±2% rH between 20% and 80% rH
System Operation
Temperature 32° to 122°F (0 to 50°C)
Humidity 0 to 95% RH, Non-condensing
Power In 20 to 30 VAC; 18 to 28 VDC;
Consumption 200 mA @ 24 VDC
Dimensions 3.0 (w) x 4.6 (h) x 1.5 (d) in (11.8 x 7.7 x 3.7 cm)
Weight .44 lbs (.20 kg)
Enclosure ABS Alloy
Display TFT, Multicolor graphical touch screen display; 1.9 (w) x 2.6 (h) in (4.9 x 6.5 cm) (Optional with Analog units)
Languages English, French for first release
Outputs
Analog 4-20 mA, 0-10VDC selectable
Digital Modbus RTU, BACnet MS/TP, LON
Relay 3 Amps, 250 VAC resistive, and 30 VDC SPDT; Field configurable set point & hysteresis
Override Selectable on Display Units
Mounting Options
Wall Mount P22
Duct Mount P54
Certifications
US ANSI/UL 61010-1
Canada CAN/CSA C22.2 No. 61010-1
Europe CE EN 13779-2007
Warranty 5 years

Choose your unit based on the following options:

-CO2 / VOC Sensors-

-Wall Mount / Duct Mount-

-Analog / Digital Output-

-Relay-

-Temp & and RH-

Ductmount Kit

ORDERING INFORMATION
Wall Mounted, CO2 monitor, Analog Output:
IAQ-WAC-D IAQpoint2, wall mount, analog, display $290
IAQ-WAC-R-D IAQpoint2, wall mount, analog, relay display $300
IAQ-WAC-TRH-D IAQpoint2, wall mount, analog, temp & RH, display $340
IAQ-WAC-TRH-R-D IAQpoint2, wall mount, analog, temp & RH, relay, display $350
Wall Mounted, VOC monitor, Analog Output:
IAQ-WAV-D IAQpoint2, wall mount, analog, display $340
IAQ-WAV-R-D IAQpoint2, wall mount, analog, relay display $350
IAQ-WAV-TRH-D IAQpoint2, wall mount, analog, temp & RH, display $390
IAQ-WAV-TRH-R-D IAQpoint2, wall mount, analog, temp & RH, relay, display $400
Wall Mounted, CO2 monitor, Digital Output (BACnet and Modbus selectable)
IAQ-WNC-D IAQpoint2, wall mount, Network, display $340
IAQ-WNC-R-D IAQpoint2, wall mount, Network, relay display $350
IAQ-WNC-TRH-D IAQpoint2, wall mount, Network, temp & RH, display $390
IAQ-WNC-TRH-R-D IAQpoint2, wall mount, Network, temp & RH, relay, display $400
Wall Mounted, VOC monitor, Digital Output (BACnet and Modbus selectable)
IAQ-WNV-D IAQpoint2, wall mount, Network, display $390
IAQ-WNV-R-D IAQpoint2, wall mount, Network, relay display $400
IAQ-WNV-TRH-D IAQpoint2, wall mount, Network, temp & RH, display $440
IAQ-WNV-TRH-R-D IAQpoint2, wall mount, Network, temp & RH, relay, display $450

Duct Mounted, CO2 monitor, Analog Output:
IAQ-DAC-D IAQpoint2, wall mount, analog, display $355
IAQ-DAC-R-D IAQpoint2, wall mount, analog, relay display $365
IAQ-DAC-TRH-D IAQpoint2, wall mount, analog, temp & RH, display $405
IAQ-DAC-TRH-R-D IAQpoint2, wall mount, analog, temp & RH, relay, display $415
Duct Mounted, VOC monitor, Analog Output:
IAQ-DAV-D IAQpoint2, wall mount, analog, display $405
IAQ-DAV-R-D IAQpoint2, wall mount, analog, relay display $415
IAQ-DAV-TRH-D IAQpoint2, wall mount, analog, temp & RH, display $455
IAQ-DAV-TRH-R-D IAQpoint2, wall mount, analog, temp & RH, relay, display $465
Duct Mounted, CO2 monitor, Digital Output (BACnet and Modbus selectable)
IAQ-DNC-D IAQpoint2, wall mount, Network, display $405  
IAQ-DNC-R-D IAQpoint2, wall mount, Network, relay display $415
IAQ-DNC-TRH-D IAQpoint2, wall mount, Network, temp & RH, display $455
IAQ-DNC-TRH-R-D IAQpoint2, wall mount, Network, temp & RH, relay, display $465
Duct Mounted, VOC monitor, Digital Output (BACnet and Modbus selectable)
IAQ-DNV-D IAQpoint2, wall mount, Network, display $455
IAQ-DNV-R-D IAQpoint2, wall mount, Network, relay display $465
IAQ-DNV-TRH-D IAQpoint2, wall mount, Network, temp & RH, display $505
IAQ-DNV-TRH-R-D IAQpoint2, wall mount, Network, temp & RH, relay, display $515