AC Voltage Isolated Transducer TZ-5EA

     Features
  • DC power supply 24VDC
  • DIN rail mounting
  • Input/Output/Power supply isolated
  • This terminal block-integrated signal converter converts alternate current to a DC signal best suitable for the measurement control equipment input. With the true RMS value operation method, this converter ensures high reliability against distorted waves.
  • download .pdf file

TZ-5EA Common Specifications
Base Accuracy ±0.2% F.S (5 to 100%F.S)(25±2ºC)
±1.0% F.S (0 to 5% F.S) (25±2ºC)
Power Supply Variation ±0.06 % F.S -( ±0.5% to the input of 0 to 5%)
Load resistance variation ±0.06% F.S
Temperature characterisitc ±0.02 % F.S/ºC
Frequency variation ±0.2% F.S ( based on 60Hz)
Vibration resistance Frequency: 10 to 55Hz; amplitude (half): 0.15mm to 10 sweeps of 5 min each in X,Y and Z directions
Response Time less than 700 msec (TYP) (0-90%)
Front adjustments ±5% for zero and span
Insulation resistance Between input and output/power supply: more than 100Mohm at 500VDC
Dielectric strength Between input and output/power supply: for 1 min at 1500VAC
Power supply voltage 24VDC ±10%
Consuming current Less than 25mA (at voltage output 24 VDC) //Less than 40 mA (at current output 24VDC)
Operating ambient temp -5 - 50ºC
Operating ambient humidity Less than 90% RH (No-condensing)
Storage Temp -10 to 70ºC
Storage Humidity Less than 60% RH (no condensing)
weight approx 80g
 
 
INPUT MODULES -
 
Code # Input Signal Input Resistance Input Range
1
0 to 35V AC
more than 200Kohm
Less than 150%
2 0 to 100V AC more than 1Mohm
3 0 to 110V AC
4 0 to 200V AC
5 0 to 220V AC
Y

Limit of specifications:

Span: less than 300V AC and more than 0 A AC
Input Frequency: 40 to 1000Hz
*Note: a measurement error may become larger when higher with harmonic waves exceeding the input frequency

 
OUTPUT MODULES -
 
Code # Output Signal Allowable Load Resistance
0 0 - 5V DC More than 2 Kohm
1 1 - 5V DC
2 0 - 10V DC More than 4Kohm, negative output: more than 10Kohm
3 -10 - 10V DC
4 -2 -2VCD More than 2Kohm, negative output: more than 10Kohm
5 -2.5 - 2.5 VDC
6 -5 - 5 VDC
7 0 - 4VDC More than 2Kohm
A 4 - 20mA DC Less than 550ohm
B 0 - 20mA DC
Y Voltage ouput: less than +15 VDC and more than -12 VDC
Minimum span: less than +27 VDC and more than 0.06 VDC
Road resistance: 10Kohm at output exceeding 10V, and a negative output
Base accuracy: ±0.25 %F.S and temperature characterisitc ±0.03 %F.S/ºC for a span of less than 1V
Current output: Less than +20 mADC and more than 0 mADC
Minimum Span: Less than +20 mADC and more than 1 mADC -- outputs can be reversed for both voltage and current outputs

   

Ordering Information
TZ-5EA Configure Input/Output in Store
$258.00
 

Topac Inc. 231 CJC Highway, Suite 103 Cohasset MA 02025 USA
Tel: 781 740 8778 Fax: 781 740 8779
e-mail: sales@topac.com

| Home | E-mail | Online store | Inquiry form | Related |

This is a world wide web document page design layout and HTML code copyright ©2002-2003 by Topac Inc. - ALL RIGHTS RESERVED