| You can purchase online where you see the check mark |
Click on the assistant to view the contents of your shopping cart | ||
| Digital Panel Meters Standard 4.5 digit DC Voltage BCD output |
![]() |
Digital panel meters from Asahi Keiki offer impressive specifications, reliability and low cost for a variety of applications |
| AP-142 | Features
|
![]() |
| Specifications AP142 |
| Input Configuration | Single ended |
| Input Bias Current | 100 pA |
| Conversion Rate | 2.5 /sec |
| Normal mode rejection | More than 50dB (50/60Hz) |
| Zero Stability | Automatic Zero Adjustment |
| Display | LED 14.2 mm 4 1/2 digit |
| Polarity | "-" automatic |
| Decimal point | Set to any position |
| Over-range indication | When input exceeds max "0000" flashes |
| Power Supply | AC 90 - 132V AC 180 - 260V DC 5 Volts +/-5% 170 mA max. |
| Operation temperature | 0~ 50 C, 35 - 85% RH |
| Power Consumption | 2 VA |
| Dimension mm H x W x D | 48 x 96 x 73 mm DIN size |
| Weight | Approx 190 g AC version, 125 g DC version |
| Dielectric Strength | AC type ~
between input (lo)
terminal and ground DC 500 V, between power supply terminal and
input terminal, ground, common and case AC 1500 Volts for 1 min. DC type ~ Between input lo and power supply (0), DC 500 V |
| Insulation Resistance | DC 500V 100 M Ohm at above terminals |
| DC Voltage Measurement |
| Accuracy +/- 0.03% of reading +/- 1 digit (23 C +/-5 C ) |
| BCD Data Output (isolated from input (lo)) |
| At Open Collector | |
| Measured Data | negative logic transistor 'on' at logic '1' |
| Polarity Signal | transistor 'ON' at plus input |
| "Over" Signal | "1" level at overflow input |
| Printing command signal | Transistor on for approx 1 ms at every measurement completion |
| Transistor output capacity | Applied voltage 30V max,
current 10mA max saturated output voltage less than 1.2 V at 10 mA |
| At TTL level | |
| Measured Data | Tri state parallel BCD positive logic latch output |
| Polarity signal | "1" level at plus input |
| Over signal | "1" level at overflow input |
| Printing command signal | Positive pulse of ~1 mS at every measurement completion |
| TTL level fanout=2 5 V CMOS | |
| Each signal above can be changed to negative logic |
![]() |
| Click on diagram for a larger image |
| Ordering Information |
Topac Inc. 231 CJC Highway, Suite 103
Cohasset MA 02025 USA
Tel: 781 740 8778 Fax: 781 740 8779
e-mail:
sales@topac.com
| Home | E-mail | Online store | Inquiry form | Related |
This is a world wide web document page design
layout and HTML code copyright ©1999-2002 by Topac Inc. - ALL RIGHTS
RESERVED