| You can purchase online where you see the check mark |
Click on the assistant to view the contents of your shopping cart | ||
| Digital Panel
Meter High Speed Set Point Comparator |
![]() |
Digital panel meters from Asahi Keiki offer impressive specifications, reliability and low cost for a variety of applications |
| AMH-752 | Features
|
![]() |
| DC Voltage Measurement |
| Accuracy ±
0.1% of
reading ±
2 digit (a</=1)(23° C
±5°C)
normal speed mode ± 0.1% of reading ± 4 digit (23° C ±5° C)(a</=1) High speed mode 1-5V ± 0.1% of reading ± 3 digit (23°C ±5°C)(a</=1)normal speed ± 0.1% of reading ± 5 digit (23° C ±5°C)(a</=1) High speed mode |
| DC Current Measurement |
| Accuracy ±
0.2% of
reading ±
2 digit (23°C
±5°C)(a</=1)normal
speed ± 0.3% of reading ± 2 digit only for -25 range ~ normal speed ± 0.2% of reading ± 4 digit (23° C ±5°C)(a</=1) High speed mode ± 0.3% of reading ± 4 digit only for - 25 range ~ High speed mode 4-20mA ± 0.1% of reading ± 3 digit (23°C ±5°C)(a</=1)normal speed ± 0.1% of reading ± 5 digit (23° C ±5°C)(a</=1) High speed mode |
| General
Specifications Click For Diagrams |
| Measurement Block AMH-752 | ||||||||||||||||||||||||||||
| Measurement function | Specify one measuring range from DC voltage, current ranges below. | |||||||||||||||||||||||||||
| Input circuit | single ended | |||||||||||||||||||||||||||
| Number of inputs | 2 channels A & B | |||||||||||||||||||||||||||
| Operation method | Successive approximation | |||||||||||||||||||||||||||
| Input Bias Current | 1nA | |||||||||||||||||||||||||||
| Conversion Rate | 1.25 /sec to 4000 /sec for
channel 1 0.652 /sec to 2000 /sec for channel 2 |
|||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||
| Normal mode rejection | > 50dB (50/60Hz) | |||||||||||||||||||||||||||
| Display | 7 segment LED, 10 mm red monitor sub display LED 8mm green |
|||||||||||||||||||||||||||
| Display speed | 12.5/sec normal speed mode only. | |||||||||||||||||||||||||||
| Polarity | "-" automatic when result is negative | |||||||||||||||||||||||||||
| Decimal point | Set to any position | |||||||||||||||||||||||||||
| Over-range indication | LED flashes value just before overload | |||||||||||||||||||||||||||
| Maximum Display | ± 1999 ( 5 digits ) | |||||||||||||||||||||||||||
| Decimal point | set to any position | |||||||||||||||||||||||||||
| Zero Display | leading "zero" suppression | |||||||||||||||||||||||||||
| External Control AMH-752 | |
| Start/Hold | Start hold
type A Start - start terminal open (or 5V) Hold - shorting between digital common and hold terminal or 0V Sample Hold type B Only one measurement is performed from the rise of +ve or -ve pulse of more than 500 uS and the result is output |
| Digital
zero (DZ) (settable on front panel) |
Digital COM and DZ terminals are shorted, or input is set to "0", displayed as "zero" and that value is stored. A and B channels can be zeroed independently. |
| Peak Hold (PH) | Respective function is activated when COM and PH terminals are shorted or input level is set to "0" Only effects the display. |
| Valley Hold | |
| Peak Valley Hold | |
| Comparison Block AMH-752 | |||||||||||||
| Control Method | Computation by microcomputer | ||||||||||||
| Measuring range comparison |
high/Low limit setting including polarity, -1999 to + 1999 | ||||||||||||
| Setting condition | By
sampling period No setting condition for set value |
||||||||||||
|
|||||||||||||
| Comparison relay output | HH, HI, GO, LO and LL | ||||||||||||
| relay output cycle | ~ 12 .5 mS at 1ch input Conversion rate: When speed is lower than 80/sec, output of each sampling. When the speed is faster than 80/sec outputs the results at ~12.5 mS intervals |
||||||||||||
| Comparison
Relay contact capacity |
250 Volts AC
0.1A resistive load 120 Volts AC 0.5A resistive load 28 Volts DC 1 A resistive load |
||||||||||||
| Photo-coupler output | sink current 20
mA max )less than 30 V. NPN open collector. |
||||||||||||
| Photo-coupler output cycle | ~ 250 us at
the sampling speed of 4000/sec for 1 ch input for others depends on sampling speed. |
||||||||||||
| Hysteresis | Settable from 1 to 999 digits for each comparison set value | ||||||||||||
| External Control | Comparison
operation is suspended when COM and Reset terminals are shorted or
input
level is set to "0" "0" level less than 1.5 V "1" level 3 to 30 V - input current < - 5mA |
||||||||||||
| Common Specifications AMH-752 | |
| Memory Backup | Set data stored for 10 years by EEPROM |
| Temperature and humidity | 0 - 50°C, 35% to 85% RH |
| Power Supply | AC 90 - 264
V |
| Operation temperature | 0~ 50°C, 35 - 85% RH |
| Power Consumption | 5VA at 100 V AC |
| Dimension mm H x W x D | 48 x 96 x 158 DIN |
| Weight | Approx 600 g |
| Dielectric Strength | 500 V DC
between input/earth and case 500 V DC between input terminal/common, digital common, relay output transistors.. 1500 VAC between power supply terminal/common, digital common, relay common, transistor output. |
| Insulation Resistance | DC 500V 100 MOhm at above terminals |
| Sensor Power Supply | 10 V +/- 10%, 80 mA |
| Optional Outputs AMH-752 |
| BCD output (isolated from input (LO)) | |
| BCD Output | Tristate parallel BCD output, Fan out 2 |
| Polarity signal | at minus value - "1" |
| OVER signal | At overflow -
"1" |
| Printing Command Signal | at end of A/D conversion, plus pulse in ~ 500us width |
| ENABLE: | All data output
transistors arte turned "OFF" when "ENABLE" and digital common terminals are
shorted or input level is set at "0". "0" level less than 1.5 V "1" level 3 to 30 V input current < -5 mA |
| Transistor output capacity | Applied Voltage
30 V max, Current 10mA max. Output saturation voltage less than 1.2 V at 10 mA TTL output is also available |
| RS232C (isolated from input (LO)) | |
| Communication method | Full duplex |
| Synchronous method | Start and Stop |
| Transmission speed | 2400/4800/9600/19200 bps |
| Start Bit | 1 Bit |
| Data length | 7 Bit |
| Error detection | Even parity |
| Stop Bit | 2 Bits |
| Character Code | ASC II |
| Transmission control | none |
| Analog Output (isolated from input
(LO)) Any display range to output analog signal can be set |
|
| output voltage | ± 0-2.5 V |
| Resolution | 0.25 mV/digit |
| Accuracy | 0.5%FS (23° C ±5°C) |
| Over-voltage | ± 3.5 V, less than 5 V |
| Moving Average | Digital Filter Function |
| Fixed zero | 10e0 digit is fixed to "0" for display |
| Display Blanking | Blanking of LEDs on main, monitor/sub display units. |
| Ordering Information |
Topac Inc. 231 CJC Highway, Suite 103
Cohasset MA 02025 USA
Tel: 781 740 8778 Fax: 781 740 8779
e-mail:
sales@topac.com
| Home | E-mail | Online store | Inquiry form | Related |
This is a world wide web document page design
layout and HTML code copyright ©2003 by Topac Inc. - ALL RIGHTS
RESERVED