| You can purchase online where you see the check mark |
Click on the assistant to view the contents of your shopping cart | ||
| Digital Panel Meters Set Point Comparator |
![]() |
Digital panel meters from Asahi Keiki offer impressive specifications, reliability and low cost for a variety of applications |
| AM-749 | Features
|
![]() |
| DC Voltage Measurement |
| Accuracy +/- 0.03% of reading +/- 2 digit (23 C +/-5 C |
| DC Current Measurement |
| Accuracy +/- 0.1% of
reading +/- 2 digit (23 C +/-5 C +/- 0.3% of reading +/- 1 digit only for 25 range |
| General
Specifications |
| Measurement Block | |
| Measurement function | Specify one measuring range from DC voltage, current ranges below. |
| Input Circuit | Single Ended |
| Operation method | dual slope |
| Input Bias Current | 100 pA |
| Conversion Rate | 12.5 /sec (50 Hx) 15 /sec (60Hz) |
| Normal mode rejection | > 50dB (50/60Hz) |
| Display | 7 segment LED, 10 mm red monitor sub display LED 8mm green |
| Polarity | "-" automatic when result is negative |
| Decimal point | Set to any position |
| Over-range indication | 'OL' LED flashes |
| Maximum Display | +/- 99999 ( 5 digits ) |
| Decimal point | set to any position |
| Zero Display | Reading "zero" suppression |
| External Control | |
| Hold | Shorting between COM and S/H terminal or "0" level |
| Start | Open between COM and S/H terminal or "1" level |
| Digital zero | Value just before COM and DZ terminals are shorted, or input is set to "0", is displayed as "zero" and that value is stored |
| Peak Hold | Respective function is activatedd when COM and PH terminals are shorted or input level is set to "0" |
| Valley Hold | |
| Peak Valley Hold | |
| Pattern selection | Anyone of eight
patterns is settable in combination of COM terminal with any of P SEL terminals
0, 1 and 2 "0" level less than 5 volts "1" level 3 - 30 volts input current less than -5 mA |
| Comparison Block | |||||||||||||||||
| Control Method | Computation by microcomputer | ||||||||||||||||
| Measuring range comparison |
high/Low limit setting including polarity, -99999 to + 99999 | ||||||||||||||||
| Setting condition | By
sampling period No setting condition for set value |
||||||||||||||||
|
|||||||||||||||||
| Comparison
Relay contact capacity |
250 Volts AC
0.2A resistive load 120 Volts AC 0.5A resistive load 28 Volts AC 1 A resistive load |
||||||||||||||||
| Photo-coupler output | sink current 20
mA max )less than 30 V. Output saturation voltage < 1.2 Volts at 20 mA |
||||||||||||||||
| Hysteresis | Settable from 1 to 9999 digits for each comparison set value | ||||||||||||||||
| External Control | Comparison
operation is suspended when COM and r1R.RES terminals are shorted or iput
level is set to "0" "0" level less than 1.5 V "1" level 3 to 30 V - input current < - 5mA |
||||||||||||||||
| Common Specifications | |
| Memory Backup | Set data stored for 10 years by ERPROM |
| Temperature and humidity | 0 - 50 degs C, 35% to 85% RH |
| Power Supply | AC 90 - 264
V |
| Operation temperature | 0~ 50 C, 35 - 85% RH |
| Power Consumption | 5VA at 100 V AC |
| Dimension mm H x W x D | 48 x 96 x 161 DIN |
| Weight | Approx 600 gm |
| Dielectric Strength | 500 V DC
between input/earth and case 500 V DC between input terminal/common, digital common, sensor power supply and relay output. 1500 VAC between power supply terminal/common, digital common, sensor power supply case and relay output |
| Insulation Resistance | DC 500V 100 MOhm at above terminals |
| Noise rejection | Power terminals, normal/common mode +/- 1500V square waveform for 1 ns at rise, noise, width 500 ns (by noise simulation) |
| Sensor Power Supply | 10 V +/- 10%, 80 mA |
| Optional Outputs |
| BCD output (isolated from input (LO)) | |
| Measured data | Negative
logic NPN open-collector outpug |
| Polarity signal | Transistor on at minus input |
| OVER signal | Transistor on at
"OVER" input |
| Printing Command Signal | Transistor on for approx 10 ms at end of measurement |
| ENABLE: | All data output
transistors arte turned "OFF" when "ENABLE" and digital common terminals are
shorted or input level is set at "0". "0" level less than 1.5 V "1" level 3 to 30 V input current < -5 mA |
| Transistor output capacity | Applied Voltage
30 V max, Current 10mA max. Output saturation voltage less than 1.2 V at 10 mA TTL output is also available |
| RS232C (isolated from input (LO)) | |
| Communication method | Full duplex |
| Synchronous method | Start and Stop |
| Transmission speed | 2400/4800/9600/19200 bps |
| Start Bit | 1 Bit |
| Data length | 7 Bit |
| Error detection | Even parity |
| Stop Bit | 2 Bits |
| Character Code | ASC II |
| Transmission control | none |
| RS485 (isolated from input (LO)) | ||||||||||
| Communication method | 2 wire system half duplex | |||||||||
| Synchronous method | Start and Stop | |||||||||
| Transmission speed | 2400/4800/9600/19200 bps | |||||||||
| Start Bit | 1 Bit | |||||||||
| Data length | 7 Bit | |||||||||
| Error detection | Even parity BCC (Block Check Character) Check sum |
|||||||||
| Stop Bit | 2 Bits | |||||||||
| Character Code | ASC II | |||||||||
| Transmission control | none | |||||||||
|
||||||||||
| Number of connectable meters | Up to 31 units | |||||||||
| cable length | up to 500 m in total | |||||||||
| Analog Output (isolated from input
(LO)) Any display range to output analog signal can be set |
|||||||||||||
| Resolution | 16 Bits | ||||||||||||
| Output Response | < 0.5 secs | ||||||||||||
|
|||||||||||||
| Moving Average | Digital Filter Function | ||||||||||||
| Fixed zero | 10e0 digit is fixed to "0" for display | ||||||||||||
| Display Blanking | Blanking of LEDs on main, monitor/sub display units. | ||||||||||||
![]() |
| Click for larger image |
| Ordering Information |
Topac Inc. 231 CJC Highway, Suite 103
Cohasset MA 02025 USA
Tel: 781 740 8778 Fax: 781 740 8779
e-mail:
sales@topac.com
| Home | E-mail | Online store | Inquiry form | Related |
This is a world wide web document page design
layout and HTML code copyright ©1999 by Topac Inc. - ALL RIGHTS
RESERVED