Digital panel meters from Asahi Keiki offer impressive specifications, reliability and low cost for a variety of applications |
| Discontinued 1/31/03 | |
| AM-164A | Features
|
![]() |
| Specifications |
| Input Configuration | Single Ended impedance approx 10MOhm |
| Rectifier Circuit | True RMS value is obtained in AC/DC converter in the analog operation method using transistor Vbe nlc |
| Conversion rate | 2.5/sec |
| Response Speed | Approx 1 sec ( 10 ~ 90% ) |
| Crest Factor | 4:1 at full scale |
| Zero Stability | Automatic zero adjustment |
| Zero Display | Leading zero suppression |
| Display | LED 10 mm 4 digit |
| Decimal point | Set to any position |
| Over-range indication | When input exceeds 200% flash '0000' |
| Power Supply | AC90-132V AC 180-264V |
| Power consumption | max 40 mA @ 24VDC |
| Operation temperature | 0~ 50 C, 35 - 85% RH |
| Dimension mm H x W x D | 48 x 96 x 144 mm DIN size |
| Weight | Approx 480 gm |
| Dielectric Strength | Input (lo) and earth E,
COM DC 500V Between power supply and input, earth, relay output 1500V AC 1 min |
| Insulation Resistance | DC 500V 100 MOhm at above terminals |
| Control System | 8 bit microcomputer |
| Setting range | 0-9999 |
| Comparative conditions | Indication > High set point
- HI High set point >/=indication>/=low set point - GO Indication < low set point - LO |
| Relay Contact Capacity | AC 250 V 0.1 A resistive
load AC 120 V 0.5 A resistive load DC 28 V 1.0 A resistive load |
| AC Voltage
Measurement Accuracy +/-0. 2% of reading +/- 20 digit (23degsC+/-5degs C) +/- 0.3% of reading +/2- digit only for AM-164A-15 |
| AC Current
Measurement Accuracy +/-0. 5% of reading +/- 20 digit (23degsC+/-5degs C) +/-0. 7% of reading +/- 20 digit (23degsC+/-5degs C for AM-164A-25 and AM-164A-26) |
| BCD Data Output (isolated from input (lo)) |
| At Open Collector | |
| Measured Data | negative logic transistor 'on' at logic '1' |
| "Over" Signal | "1" level at overflow input |
| Printing command signal | Transistor on for approx 1 ms at every measurement completion |
| Transistor output capacity | Applied voltage 30V max,
current 10mA max saturated output voltage less than 1.2 V at 10 mA |
| At TTL level | |
| Measured Data | Tri state parallel BCD positive logic latch output |
| Over signal | "1" level at overflow input |
| Printing command signal | Positive pulse of ~1 mS at every measurement completion |
| TTL level fanout=2 5 V CMOS | |
| Each signal above can be changed to negative logic |
| Analog Output |
| Measured Data | 0-1 Volt "0.5% F.S (23 C+/-5C) 0.1 mV / digit 20 KOhms or more load |
![]() |
| Click image for larger view |
| Ordering Information |
Related Products