| Digital Panel Meters DC Voltage and Current with BCD output 100/sec conversion rate |
![]() |
Digital panel meters from Asahi Keiki offer impressive specifications, reliability and low cost for a variety of applications |
| APH114 | Features
|
![]() |
| Specifications |
| Input Configuration | Single Ended |
| Input Bias Current | 2 nA typical |
| Conversion Rate | 100/sec |
| Zero Stability | Automatic Zero Adjustment |
| Zero Display | Leading zero suppression |
| Display | LED 14.2mm 4 digit |
| Polarity | "-" automatic |
| Decimal point | Set to any position |
| Over-range indication | 'oL' flashes |
| Power Supply | AC 90 - 130 Volts AC 180 - 264 V |
| Operation temperature | 0~ 50 C, 35 - 85% RH |
| Power Consumption | 2.5VA |
| Dimension mm H x W x D | 48 x 96 x 97.5 mm DIN size |
| Weight | Approx 250 g |
| Dielectric Strength | Between input
/DG 500V/1min Between power supply input ground, case, DG AC 1500 Volts for 1 min. |
| Insulation Resistance | DC 500V 100 MOhm at above terminals |
| BCD Data Output (isolated from input (lo)) |
| Measured Data | negative logic transistor 'on' at logic '1' |
| Polarity Signal | transistor 'ON' at plus input |
| "Over" Signal | "1" level at overflow input |
| Printing command signal | Transistor on for approx 1 ms at every measurement completion |
| Transistor output capacity | Applied voltage 30V max,
current 10mA max saturated output voltage less than 1.2 V at 10 mA |
| At TTL | |
| Measured Data | Tri state parallel BCD positive logic latch output |
| Polarity signal | "1" level at minus input |
| Over signal | "1" level at overflow input |
| Printing command signal | Positive pulse of ~5 mS at every measurement completion |
| TTL level fanout=2 5 V CMOS | |
| Enable | |
| Shorted ENABLE and DG terminals transistor "OFF" ( high impedance status at TTL ) | |
| "0" level | 0 ~ 1.5V |
| "1" level | 3.5 ~ 5.0 V |
| Input current | -0.5 mA |
| DC Voltage measurement |
| Accuracy +/- 0.03% of reading
+/- 3 digit (23 C +/-5 C) |
| Model | Range | Display Adjustable | Internal Resistance | input protection |
| APH-114-12 | +/- 999.9 mV | Offset +/- 9999 full scale 0 ~ +/- 9999 |
100 MOhm | +/- 250 V |
| APH-114-13 | +/- 9.999 V | 1 MOhm | +/- 250 V |
| 1 - 5 V measurement |
| Accuracy +/- 0.03% of reading
+/- 3 digit (23 C +/-5 C) |
| Model | Range | Display Adjustable | Internal Resistance | input protection |
| APH-114-1V | 1 -5 V | Offset +/- 9999 full scale 0 ~ +/- 9999 |
1 MOhm | +/- 250 V |
| 4 - 20 mA current measurement |
| Accuracy +/- 0.03% of reading
+/- 3 digit (23 C +/-5 C) |
| Model | Range | Display Adjustable | Internal Resistance | input protection |
| APH-114-2A | 4 - 20 mA | Offset +/- 9999 full scale 0 ~ +/- 9999 |
1 MOhms | +/- 70 mA |
![]() |
| Ordering Information |